The 26RCA is the Kohler that large-home buyers put against the Generac 26kW, and an owner who chose it gave three reasons: 24kW on natural gas instead of 22.5, hydraulic lifters that never need adjustment, and lower fuel use. Several quotes put it on two 200-amp switches or a 400-amp service for homes with multiple air conditioners, electric ovens and dryers, and one Tampa owner ran it for 150 hours through Hurricane Milton.
Setup draws many of the owner questions. The default unloaded cycle exercise makes it surge, and the advice is to change it to unloaded full speed; an owner with milky oil in a cold Ohio winter found the manual also offers an EcoExercise that runs monthly for 90 seconds in cold climates. One propane buyer was told to plan a 500-gallon tank at minimum: at about a gallon an hour on an average 2kW load, ten days of running needs roughly 250 to 275 gallons, and a tank only fills to 80 percent. Natural gas homes should check meter capacity. By one account the manual requires oil checks every 24 hours of runtime, and the 26's oil change interval is 150 hours. Load-shed modules are debated; installers on two owners' jobs fitted Generac-labelled modules, which one person put down to the cost of Kohler's, and an owner with a 5-ton heat pump drawing 142 locked-rotor amps is weighing a soft start.
The biggest air-cooled Kohler makes sense for large natural-gas homes that have a certified dealer for startup. Against the Generac 26kW, owners saw quotes from nearly identical to $5,000 to $7,000 more for the Kohler. One Houston shopper also listed the Briggs 26kW and Cummins 20kW, and one all-electric home went to a liquid-cooled 30kW Kohler with four load-shed modules at $47,000 after a 26kW quote came without the right load shedding.